PL
  • ENG
  • All categories
  • Connectors
  • Lightning holders
  • Lightning conductors
  • Straighteners
  • Lightning protection pipes
  • Earthings and earthing elements
  • Lightning protection masts
  • High voltage cable and accessories
  • Insulated rods and brackets
  • Other products
Login
Sign in
EN
  • PL
Products
Connectors
Cross connectors
Connection sleeves
Test connectors
Universal clamps
Lightning holders
Top holders
Holders for ridge tiles
Angular holders
Universal holders
Round conductor folders
Holders for metal roof
Tile holders
Straight holders
Tension holders
Anchors
Holders with a metal base
Concrete holders in plastic
Turnbuckles screws
Universal pipe holders
Plastic holders
Lightning conductors
Round conductors
Flat cables
Straighteners
Straighteners with manual drive
Straightener with electric drive
Lightning protection pipes
Lightning protection pipes and accessories
Earthings and earthing elements
Earthings
Tips, mallets, connections
Earthing connectors
Components mounted in the building’s reinforcement
Tape holder
Control boxes
Equipotential connections
Lightning protection masts
Free-standing masts
Free-standing masts for elevated terminals
Insulated free standing masts for elevated air terminals
Free-standing masts isolated for high-voltage cable
Wall/structure-mounted masts
Masts on concrete foundation
Fixings for lightning protection masts and accessories
High voltage cable and accessories
High voltage cable
HVC equipment
HVC handles
Insulated rods and brackets
Insulated bars
Brackets and connectors
Insulated bracket
Other products
About usNewsDownloadsRealizationsContact
O nas
Wall/structure-mounted masts/Lightning protection masts/

Product "" not found for set filters. Would you like to search through the entire catalogue?

Filters

Categories
  • Connectors (93)
  • Lightning holders (583)
  • Lightning conductors (15)
  • Straighteners (6)
  • Lightning protection pipes (11)
  • Earthings and earthing elements (115)
  • Lightning protection masts (182)
  • High voltage cable and accessories (24)
  • Insulated rods and brackets (19)
  • Other products (26)
Filters
Label
Manufacturer
Brand
Availability
L1/L2/L3/L4/L5/L6/L7/L8/L9/L10/L11/L12 [mm]
Material
Height / lenght [mm]
Diameter [mm]
Wind zone
Round conductor/flat tape range [mm]
Others
Thread
Side insulator [pcs]
Categories
  • Connectors (93)
  • Lightning holders (583)
  • Lightning conductors (15)
  • Straighteners (6)
  • Lightning protection pipes (11)
  • Earthings and earthing elements (115)
  • Lightning protection masts (182)
  • High voltage cable and accessories (24)
  • Insulated rods and brackets (19)
  • Other products (26)
Filters
Label
Manufacturer
Brand
Availability
L1/L2/L3/L4/L5/L6/L7/L8/L9/L10/L11/L12 [mm]
Material
Height / lenght [mm]
Diameter [mm]
Wind zone
Round conductor/flat tape range [mm]
Others
Thread
Side insulator [pcs]
Category:

Wall/structure-mounted masts

Found items
58
/ 4
Material aluminum, electro-galvanized steel
Round conductor/flat tape range [mm] Ø8-10
Height / lenght [mm] 1000
Diameter [mm] Ø12
L1/L2/L3/L4/L5/L6/L7/L8/L9/L10/L11/L12 [mm] .../1000/.../.../.../.../.../.../.../.../.../...
Wind zone up tu 950 m above sea level – maximum wind speed 30 m/s
Weight [kg] 1.6
Material aluminum, fiberglass, galvanized steel
Height / lenght [mm] 1500
Diameter [mm] Ø10-36
L1/L2/L3/L4/L5/L6/L7/L8/L9/L10/L11/L12 [mm] 500/.../.../.../.../.../.../.../1000/.../.../...
Wind zone up tu 950 m above sea level – maximum wind speed 30 m/s
Weight [kg] 2.1
Others The high voltage cable and its mounting accessories are not included in the mast. The diagram of the installation of the high voltage cable can be found in the Assembly instruction No. 20: "Instructions for the installation of the high voltage cable for i
Material aluminum, electro-galvanized steel
Height / lenght [mm] 1000
Diameter [mm] Ø12
L1/L2/L3/L4/L5/L6/L7/L8/L9/L10/L11/L12 [mm] .../1000/.../.../.../.../.../.../.../.../.../...
Wind zone up tu 950 m above sea level – maximum wind speed 30 m/s
Thread M12
Weight [kg] 0.3
Others When installing the mast on a sloping roof, we recommend using the adjusting screw (catalog number AH40171)
Material aluminum, electro-galvanized steel
Round conductor/flat tape range [mm] Ø8-10
Height / lenght [mm] 1500
Diameter [mm] Ø12
L1/L2/L3/L4/L5/L6/L7/L8/L9/L10/L11/L12 [mm] .../1500/.../.../.../.../.../.../.../.../.../...
Wind zone up tu 950 m above sea level – maximum wind speed 30 m/s
Weight [kg] 1.8
Material aluminum, fiberglass, galvanized steel
Height / lenght [mm] 2000
Diameter [mm] Ø10-40
L1/L2/L3/L4/L5/L6/L7/L8/L9/L10/L11/L12 [mm] 500/.../.../.../500/.../.../.../1000/.../.../...
Wind zone up tu 950 m above sea level – maximum wind speed 30 m/s
Weight [kg] 2.8
Others The high voltage cable and its mounting accessories are not included in the mast. The diagram of the installation of the high voltage cable can be found in the Assembly instruction No. 20: "Instructions for the installation of the high voltage cable for i
Material aluminum, electro-galvanized steel
Height / lenght [mm] 1500
Diameter [mm] Ø12
L1/L2/L3/L4/L5/L6/L7/L8/L9/L10/L11/L12 [mm] .../1500/.../.../.../.../.../.../.../.../.../...
Wind zone up tu 950 m above sea level – maximum wind speed 30 m/s
Thread M12
Weight [kg] 0.5
Others When installing the mast on a sloping roof, we recommend using the adjusting screw (catalog number AH40171)
Material aluminum, electro-galvanized steel
Round conductor/flat tape range [mm] Ø8-10
Height / lenght [mm] 2000
Diameter [mm] Ø12
L1/L2/L3/L4/L5/L6/L7/L8/L9/L10/L11/L12 [mm] .../2000/.../.../.../.../.../.../.../.../.../...
Wind zone up tu 950 m above sea level – maximum wind speed 30 m/s
Weight [kg] 2.1
Material aluminum, fiberglass, galvanized steel
Height / lenght [mm] 3000
Diameter [mm] Ø10-40
L1/L2/L3/L4/L5/L6/L7/L8/L9/L10/L11/L12 [mm] 1000/.../.../.../1000/.../.../.../1000/.../.../...
Wind zone up tu 950 m above sea level – maximum wind speed 30 m/s
Weight [kg] 3.7
Others The high voltage cable and its mounting accessories are not included in the mast. The diagram of the installation of the high voltage cable can be found in the Assembly instruction No. 20: "Instructions for the installation of the high voltage cable for i
Material aluminum, electro-galvanized steel
Height / lenght [mm] 2000
Diameter [mm] Ø12
L1/L2/L3/L4/L5/L6/L7/L8/L9/L10/L11/L12 [mm] .../2000/.../.../.../.../.../.../.../.../.../...
Wind zone up tu 950 m above sea level – maximum wind speed 30 m/s
Thread M12
Weight [kg] 0.7
Others When installing the mast on a sloping roof, we recommend using the adjusting screw (catalog number AH40171)
Material aluminum, electro-galvanized steel
Round conductor/flat tape range [mm] Ø8-10
Height / lenght [mm] 2500
Diameter [mm] Ø10-22
L1/L2/L3/L4/L5/L6/L7/L8/L9/L10/L11/L12 [mm] 1000/.../1000/500/.../.../.../.../.../.../.../...
Wind zone up tu 950 m above sea level – maximum wind speed 30 m/s
Weight [kg] 2.4
Material aluminum, fiberglass, galvanized steel
Height / lenght [mm] 4000
Diameter [mm] Ø10-40
L1/L2/L3/L4/L5/L6/L7/L8/L9/L10/L11/L12 [mm] 1000/.../.../.../2000/.../.../.../1000/.../.../...
Wind zone up tu 950 m above sea level – maximum wind speed 30 m/s
Weight [kg] 5.2
Others The high voltage cable and its mounting accessories are not included in the mast. The diagram of the installation of the high voltage cable can be found in the Assembly instruction No. 20: "Instructions for the installation of the high voltage cable for i
Material aluminum, electro-galvanized steel
Height / lenght [mm] 2500
Diameter [mm] Ø10-22
L1/L2/L3/L4/L5/L6/L7/L8/L9/L10/L11/L12 [mm] 1000/.../1000/500/.../.../.../.../.../.../.../...
Wind zone up tu 950 m above sea level – maximum wind speed 30 m/s
Thread M20
Weight [kg] 1.3
Others When installing the mast on a sloping roof, we recommend using the adjusting screw (catalog number AH40181)
Material aluminum, electro-galvanized steel
Round conductor/flat tape range [mm] Ø8-10
Height / lenght [mm] 3000
Diameter [mm] Ø10-22
L1/L2/L3/L4/L5/L6/L7/L8/L9/L10/L11/L12 [mm] 1000/.../1000/1000/.../.../.../.../.../.../.../...
Wind zone up tu 950 m above sea level – maximum wind speed 30 m/s
Weight [kg] 2.8
Material aluminum, fiberglass, galvanized steel
Height / lenght [mm] 5000
Diameter [mm] Ø10-40
L1/L2/L3/L4/L5/L6/L7/L8/L9/L10/L11/L12 [mm] 1000/.../.../.../3000/.../.../.../1000/.../.../...
Wind zone up tu 950 m above sea level – maximum wind speed 30 m/s
Weight [kg] 6.7
Others The high voltage cable and its mounting accessories are not included in the mast. The diagram of the installation of the high voltage cable can be found in the Assembly instruction No. 20: "Instructions for the installation of the high voltage cable for i
Material aluminum, electro-galvanized steel
Height / lenght [mm] 3000
Diameter [mm] Ø10-22
L1/L2/L3/L4/L5/L6/L7/L8/L9/L10/L11/L12 [mm] 1000/.../1000/1000/.../.../.../.../.../.../.../...
Wind zone up tu 950 m above sea level – maximum wind speed 30 m/s
Thread M20
Weight [kg] 1.8
Others When installing the mast on a sloping roof, we recommend using the adjusting screw (catalog number AH40181)
Found items
58
/ 4

In the offer of AH Hardt Lightning Protection System you can find the following product categories connectors, earthings and earthing elements, high voltage cables, insulated rods and brackets, lightning holders, lightning conductors, lightning protection masts, lightning protection masts, lightning protection pipes and straighteners.

Contact

AH Hardt sp.j.

Cholerzyn 215

32-060 Liszki

Monday – Friday: 8:00 – 16:00

tel: 12 658-66-77/88

handlowy@ah.com.pl

Tax number: PL6790168262.

KRS: 0000120755

REGON: 350114787

Account number:
27 8589 0006 0000 0017 2606 0002

IBAN:
PL16858900060000001726060006

Sitemap

  • About us
  • Download
  • Contact
  • Products
  • Realizations
  • Privacy policy
  • Privacy and sales policy

Social media




Quality Certified by Bureau Veritas


2025 AH Hardt Lightning protection systems
Powered by
Home
Menu
Cart
Wishlist
Log in